ASSOCIATED RESEARCH 7650 CALIBRATION and ASSOCIATED RESEARCH 7650 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the ASSOCIATED RESEARCH 7650 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   ASSOCIATED RESEARCH 7650   Description / Specification:    
ASSOCIATED RESEARCH 7650 5 kVAC/DC HypotULTRA III Hipot tester, Insulation Resistance

The Associated Research 7650 HypotULTRA III is a 5 kVAC / 5kVDC Hipot tester with a built-in Insulation Resistance and Continuity Tester. It can perform a low current continuity test simultaneously with the Hipot test, or use the separate continuity test mode to perform an independent continuity test. In this mode, the range is adjustable from 0.01 to 10 ohms. In addition, point-to-point continuity test can be run through the optional built-in scanner. The AR 7650 has up to 30mA of current is available in AC Hipot mode and 10 mA in DC Hipot mode with resolutions of 1 microamps in AC and 0.1 microamps in DC. The Insulation Resistance measurement range of the HypotULTRA III allows for measurements up to 50 Gigohms. It has an enhanced graphic LCD display with analog bar graph for monitoring test results. Specifications. Dielectric Withstand Test Mode Output Rating: 5000 V @ 30 mA AC, 5000 V @ 10 mA DC. Output Adjustment Range: 0 - 5.00 KV AC, 0 - 5.00 KV DC. Voltage Setting Resolution: 1 V. Voltage Setting Accuracy: ± (2% of setting + 5 V) (Adjustable during operation. Disabled when key lockout is active). Maximum Limit AC Range: 0.00 - 9.999 mA, Resolution 0.001 mA. Maximum Limit DC Range: 0.00 - 999.9 µA, Resolution 0.1 µA. Arc Detection Range: 1 – 9. AC Voltage Waveform: Sine Wave, Crest Factor = 1.3 - 1.5. Output Frequency Range: 50 or 60 Hz, User Selectable. Ground Continuity Current: DC 0.1 A ± 0.01 A (Total Resistance 0.00 ohm - 33.0 ohm), DC 0.01 A ± 0.001 A (Total Resistance 31.0 ohm - 330 ohm), DC 0.001 A ± 0.0001 A (Total Resistance 310 ohm - 2000 ohm). Insulation Resistance Test Mode Output Voltage Range: 50 - 1000 VDC, Resolution 1 Volt, Accuracy ± (2% of setting + 2 V). Resistance Display Range: 0.05 M-ohm – 50,000 M-ohm (5 Digit, Auto Ranging). Options. Scanning Matrix, 4 or 8 port high voltage switching matrix with continuity.



 

Standard Calibration $405.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the ASSOCIATED RESEARCH 7650. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Crest Factor
Crest factor or peak-to-average ratio (PAR) is a measurement of a waveform, calculated from the peak amplitude of the waveform divided by the RMS value of the waveform

Linearity
Linearity is the relative difference between the displayed power ratio, Dx/D0, and the actual (true) power ratio Px/P0 caused by changing the displayed power level from the reference level, D0, to an arbitrary displayed level, Dx.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.

Sensitivity
Sensitivity is the minimum magnitude of input signal required to produce a specified output signal having a specified signal-to-noise ratio, or other specified criteria.


Please contact us for your ASSOCIATED RESEARCH 7650 CALIBRATION and/or ASSOCIATED RESEARCH 7650 5 kVAC/DC HypotULTRA III Hipot tester, Insulation Resistance REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: